咨询热线:

136-8688-4195
油研
当前位置:主页 > 液压知识堂

液压知识堂

VICKERS variable piston pump PVXS-090-M-R-DF-0000 parameters

更新时间:2026-03-31 17:57:47  

Technical Parameters for VICKERS Variable Piston Pump PVXS-090-M-R-DF-0000

1. Model Interpretation

The model designation PVXS-090-M-R-DF-0000 is structured to reflect the pump’s key specifications, as follows:
  • PVXS: Series identifier, indicating the VICKERS PVXS series variable displacement axial piston pump
  • 090: Displacement specification, 90 cm³/rev (cubic centimeters per revolution)
  • M: Configuration, middle unit
  • R: Main port orientation, radial (side ports)
  • DF: Control mode, differential pressure control (DF type)
  • 0000: Design and specification code, standard factory settings

2. Technical Specifications

Specification Item
Value
Unit
Displacement
90
cm³/rev
Rated Pressure (100% duty cycle)
350
bar
Maximum Pressure (ISO 5598:2008)
420
bar
Rated Speed
1800
r/min
Minimum Inlet Pressure (Absolute)
0.85
bar
Hydraulic Fluid Temperature Range
-25 ~ 90
°C
Viscosity Range (Continuous Operation)
10 ~ 75
cst
Hydraulic Fluid Requirement
Hydraulic oil complying with DIN 51524 Part 2
-
Shaft Seal Type
Single unit shaft seal (FKM material)
-
Control Mode
Differential pressure control (DF)
-
Configuration Type
Middle unit (M)
-
Port Orientation
Radial (side ports, R)
-